IEC 60112:2003+AMD1:2009 CSV
|
Method for the determination of the proof and the comparative tracking indices of solid insulating materials
|
EN 60068-2-75:2014
|
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
|
IEC 60127:1974
|
Cartridge fuse-links for miniature fuses
|
IEC 60695-2-1:1991
|
Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance
|
HD 214 : 200S2
|
RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS
|
EN 60065:2014/AC:2017-01
|
AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
|
EN 60127-6:2014
|
Miniature fuses - Part 6: Fuse-holders for miniature fuse-links
|
IEC 60364-4-442:1993+AMD1:1995+AMD2:1999 CSV
|
Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 442: Protection of low-voltage installations against temporary overvoltages and faults between high-voltage systems and earth
|
EN 60127-1:2006/A2:2015
|
MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINKS
|
IEC 60999-2:2003
|
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included)
|
HD 625.1 : 200S1
|
INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PRINCIPLES, REQUIREMENTS AND TESTS
|
EN 60417-1:2002
|
GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - PART 1: OVERVIEW AND APPLICATION
|
EN 60127-3:2015
|
Miniature fuses - Part 3: Sub-miniature fuse-links
|
EN 60127-2:2014
|
Miniature fuses - Part 2: Cartridge fuse-links
|
EN 60417-2:1999
|
Graphical symbols for use on equipment - Part 2: Symbol originals
|
IEC 60999-1:1999
|
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
|
EN 132400 : 1994 AMD 4 2001
|
SECTIONAL SPECIFICATION: FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS (ASSESSMENT LEVEL D)
|
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV
|
Degrees of protection provided by enclosures (IP Code)
|
IEC 60669-1:2017
|
Switches for household and similar fixed-electrical installations - Part 1: General requirements
|
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV
|
Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
|
IEC 60068-2-75:2014
|
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
|
EN 60999-1:2000
|
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included)
|
EN 60529:1991/AC:2016-12
|
DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
|
HD 384.4.442 : 200S1
|
ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 44: PROTECTION AGAINST OVERVOLTAGES - SECTION 442: PROTECTION OF LOW-VOLTAGE INSTALLATIONS AGAINST FAULTS BETWEEN HIGH-VOLTAGE SYSTEMS AND EARTH
|
EN 60127-5:2017
|
Miniature fuses - Part 5: Guidelines for quality assessment of miniature fuse-links
|
EN 60127-4:2005/A2:2013
|
Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types
|
IEC 60664-1:2007
|
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
|
EN 60721-3-3 : 95 AMD 2 97
|
CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS
|