1 - AS 3547-1997 BREATH ALCOHOL TESTING DEVICES FOR PERSONAL USE
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 OBJECTIVE
6 - 1.3 CLASSIFICATION
6 - 1.4 REFERENCED DOCUMENTS
6 - 1.5 DEFINITIONS
6 - 1.5.1 Alcohol
6 - 1.5.2 Automatic gas sampling system
6 - 1.5.3 Blood alcohol concentration (BAC)
7 - 1.5.4 Breath alcohol testing device
7 - 1.5.5 Calibration
7 - 1.5.6 Calibration period
7 - 1.5.7 Calibration setting
7 - 1.5.8 Caution result
7 - 1.5.9 Corridor air
7 - 1.5.10 Deep lung air
7 - 1.5.11 Designated blood alcohol concentration
7 - 1.5.12 Expiry date
7 - 1.5.13 Negative result
7 - 1.5.14 Nominated flow rate
7 - 1.5.15 Normal room temperature
7 - 1.5.16 Positive result
7 - 1.5.17 Recalibration
7 - 1.5.18 Recovery time
7 - 1.5.19 Self-calibration
8 - SECTION 2 TYPE 1 DEVICES
8 - 2.1 SCOPE
8 - 2.2 PERFORMANCE REQUIREMENTS
8 - 2.2.1 Gas sample
8 - 2.2.2 Legibility
8 - 2.3 TESTING
8 - 2.3.1 General
8 - 2.3.2 Accuracy and flow sensitivity
8 - 2.4 INFORMATION AND MARKING
8 - 2.4.1 Information
9 - 2.4.2 Marking
10 - SECTION 3 TYPE 2 DEVICES
10 - 3.1 SCOPE
10 - 3.2 PERFORMANCE REQUIREMENTS
10 - 3.2.1 Display
10 - 3.2.2 Calibration
11 - 3.2.3 Automatic gas sampling system
11 - 3.2.4 Recovery time
11 - 3.3 TESTING
11 - 3.3.1 General
11 - 3.3.2 Qualitative Type 2 devices
12 - 3.3.3 Quantitative Type 2 devices
13 - 3.4 INFORMATION AND MARKING
13 - 3.4.1 Information
13 - 3.4.2 Marking
14 - SECTION 4 TYPE 3 DEVICES
14 - 4.1 SCOPE
14 - 4.2 PERFORMANCE REQUIREMENTS
14 - 4.2.1 Display
14 - 4.2.2 Calibration
14 - 4.2.3 Electrical safety
14 - 4.2.4 Automatic gas sampling system
14 - 4.2.5 Recovery time
15 - 4.2.6 Hygiene
15 - 4.2.7 Liquid contamination
15 - 4.3 TESTING
15 - 4.3.1 Testing before storage period
15 - 4.3.2 Testing after storage period
16 - 4.4 INFORMATION AND MARKING
16 - 4.4.1 Information
16 - 4.4.2 Marking
17 - SECTION 5 TYPE 4 DEVICES
17 - 5.1 SCOPE
17 - 5.2 PERFORMANCE REQUIREMENTS
17 - 5.2.1 General
17 - 5.2.2 Display
17 - 5.2.3 Calibration
18 - 5.2.4 Automatic gas sampling system
18 - 5.2.5 Recovery time
18 - 5.3 TESTING
18 - 5.3.1 Testing before storage period
18 - 5.3.2 Testing after storage period
19 - 5.3.3 Activation of interlock function
19 - 5.4 INFORMATION AND MARKING
19 - 5.4.1 Information
20 - 5.4.2 Marking
21 - APPENDIX A - TEST METHOD FOR BREATH ALCOHOL TESTING DEVICES USING SIMULATED EXPIRED AIR
21 - A1 SCOPE
21 - A2 PRINCIPLE
21 - A3 REAGENTS
21 - A3.1 Ethanol
21 - A3.2 Carrier gas
21 - A4 APPARATUS
21 - A4.1 Glassware
21 - A4.2 Expired air simulator
21 - A4.3 Flowmeter
21 - A4.4 Temperature measuring device
21 - A5 PROCEDURE
22 - A6 TEST REPORT
24 - APPENDIX B - TEST METHOD FOR QUALITATIVE TYPE 2 DEVICES
24 - B1 SCOPE
24 - B2 PRINCIPLE
24 - B3 PROCEDURE
24 - B3.1 General
24 - B3.2 Calibration
24 - B3.3 Testing after calibration
25 - B3.4 Storage period
25 - B3.5 Testing after storage
25 - B4 TEST REPORT
26 - APPENDIX C - TEST METHOD FOR QUANTITATIVE TYPE 2 DEVICES
26 - C1 SCOPE
26 - C2 PRINCIPLE
26 - C3 PROCEDURE
26 - C3.1 General
26 - C3.2 Calibration
26 - C3.3 Testing after calibration
27 - C3.4 Storage period
27 - C3.5 Testing after storage
27 - C4 TEST REPORT
29 - APPENDIX D - TEST METHOD FOR TYPE 3 DEVICES
29 - D1 SCOPE
29 - D2 PRINCIPLE
29 - D3 PROCEDURE
29 - D3.1 General
29 - D3.2 Calibration
29 - D3.3 Testing after calibration
30 - D3.4 Storage period
30 - D3.5 Testing after storage
31 - D4 TEST REPORT
32 - APPENDIX E - TEST METHOD FOR TYPE 4 DEVICES
32 - E1 SCOPE
32 - E2 PRINCIPLE
32 - E3 PROCEDURE
32 - E3.1 General
32 - E3.2 Calibration
32 - E3.3 Testing after calibration
34 - E3.4 Storage period
34 - E3.5 Testing after storage
35 - E4 TEST REPORT

Specifies requirements for the performance, testing and marking of disposable and re-useable breath alcohol testing devices other than those used by law enforcement authorities. Appendices include test methods for the different types of devices available.

Committee
CS-077
DocumentType
Standard
ISBN
0 7337 0934 6
Pages
30
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for the performance, testing and marking of disposable and re-useable breath alcohol testing devices for personal use, other than those devices used by the Police to obtain evidence which is used in the prosecution of drink-drivers.

Amendment 1 to AS 3547-1997 see DR 99338 First published as AS 3547-1988.Second edition 1993.Third edition 1997. First published as AS 3547-1988. Second edition 1993. Third edition 1997.

15/30325751 DC : 0 BS EN 50436-3 - ALCHOLIC INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 3: GUIDANCE FOR AUTHORITIES, DECISION MAKERS, PURCHASERS AND USERS
BS EN 50436-3:2016 Alcohol interlocks. Test methods and performance requirements Guidance for authorities, decision makers, purchasers and users
AS 1099.2.31-1990 Basic environmental testing procedures for electrotechnology Tests - Test Ec - Drop and topple, primarily for equipment
I.S. EN 50436-3:2016 ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 3: GUIDANCE FOR AUTHORITIES, DECISION MAKERS, PURCHASERS AND USERS
BS EN 50436-1:2014 Alcohol interlocks. Test methods and performance requirements Instruments for drink-driving-offender programs
PREN 50436-3 : DRAFT 2015 ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 3: GUIDANCE FOR AUTHORITIES, DECISION MAKERS, PURCHASERS AND USERS
12/30260709 DC : 0 BS EN 50436-1 - ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 1: INSTRUMENTS FOR DRINK-DRIVING-OFFENDER PROGRAMS
I.S. EN 50436-1:2014 ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 1: INSTRUMENTS FOR DRINK-DRIVING-OFFENDER PROGRAMS
AS 1099.2.6-1988 Basic environmental testing procedures for electrotechnology Tests - Test Fc - Vibration (sinusoidal)
AS/NZS 2596:2003 Seat belt assemblies for motor vehicles (ECE Regulation No. 16, MOD)
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS/NZS 2596:1995 Seat belt assemblies for motor vehicles
AS 3100-1990 Approval and test specification - General requirements for electrical equipment
PREN 50436-1 : DRAFT 2012 ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 1: INSTRUMENTS FOR DRINK-DRIVING-OFFENDER PROGRAMS
EN 50436-3:2016 Alcohol interlocks - Test methods and performance requirements - Part 3: Guidance for authorities, decision makers, purchasers and users
EN 50436-1 : 2014 COR 2016 ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 1: INSTRUMENTS FOR DRINK-DRIVING-OFFENDER PROGRAMS

View more information