IEC 61094-3:2016
Current
The latest, up-to-date edition.
Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
14-06-2016
IEC 61094-3:2016 specifies a primary method of determining the complex free-field sensitivity of laboratory standard microphones so as to establish a reproducible and accurate basis for the measurement of sound pressure under free-field conditions. It is applicable to laboratory standard microphones meeting the requirements of IEC 61094-1. It is intended for use by laboratories with highly experienced staff and specialized equipment. This second edition cancels and replaces the first edition published in 1995. This edition constitutes a technical revision.
The contents of the corrigendum of December 2016 have been included in this copy.
DevelopmentNote |
Supersedes IEC 60486 (03/2001) Stability date: 2019. (06/2016)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 61094-3 : 2016 | Identical |
DIN EN 61094-3:2015-09 (Draft) | Identical |
NF EN 61094-3 : 1996 | Identical |
CEI EN 61094-3 : 1997 | Identical |
UNE-EN 61094-3:2017 | Identical |
NEN EN IEC 61094-3 : 2016 C1 2017 | Identical |
BS EN 61094-3:2016 | Identical |
PN EN 61094-3 : 2016 AC 2017 | Identical |
SN EN 61094-3 : 2016 | Identical |
EN 61094-3:2016/AC:2017-01 | Identical |
EN 61094-3:2016 | Identical |
ANSI/ASA S1.15 PART 3:2021 | Identical |
ONORM OVE EN 61094-3 : 1996 | Identical |
NEN 11094-3 : 1996 | Identical |
GOST R IEC 61094-3 : 2001 | Identical |
BS EN 61094-4:1996 | Specification for measurement microphones Specifications for working standard microphones |
I.S. EN 61265:1998 | ELECTROACOUSTICS - INSTRUMENTS FOR MEASUREMENT OF AIRCRAFT NOISE - PERFORMANCE REQUIREMENTS FOR SYSTEMS TO MEASURE ONE-THIRD-OCTAVE BAND SOUND PRESSURE LEVELS IN NOISE CERTIFICATION OF TRANSPORT-CATEGORY AEROPLANES |
IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
EN 61265:1995 | Electroacoustics - Instruments for measurement of aircraft noise - Performance requirements for systems to measure one-third-octave band sound pressure levels in noise certification of transport-category aeroplanes |
EN 62585 : 2012 | ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER (IEC 62585:2012) |
EN 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
EN 61094-6:2005 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
EN 61094-8:2012/AC:2013 | Measurement microphones — Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
DD IEC/TS 61094-7:2006 | Measurement microphones Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones |
BS EN 61094-6:2005 | Measurement microphones Electrostatic actuators for determination of frequency response |
I.S. EN 62585:2012 | ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER (IEC 62585:2012 (EQV)) |
CEI EN 61094-6 : 2005 | MEASUREMENT MICROPHONES PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE |
11/30255884 DC : 0 | BS EN 61094-8 ED.1 - ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 8: METHODS FOR FREE-FIELD CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON |
03/305077 DC : DRAFT MAR 2003 | IEC 61094-6 ED.1 - MEASUREMENT MICROPHONES - PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE |
BS EN 61094-8:2012 | Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison |
CEI EN 61094-4 : 1997 | MEASUREMENT MICROPHONES PART 4: SPECIFICATIONS FOR WORKING STANDARD MICROPHONES |
IEEE/ANSI C63.19-2011 REDLINE | American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids |
IEC TS 61094-7:2006 | Measurement microphones - Part 7: Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones |
CEI EN 61094-8 : 2013 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 8: METHODS FOR FREE-FIELD CALIBRATION OF WORKING STANDARD MICROPHONES BY COMPARISON |
CEI EN 61265 : 1996 | ELECTROACOUSTICS - INSTRUMENTS FOR MEASUREMENT OF AIRCRAFT NOISE - PERFORMANCE REQUIREMENTS FOR SYSTEMS TO MEASURE ONE-THIRD-OCTAVE BAND SOUND PRESSURE LEVELS IN NOISE CERTIFICATION OF TRANSPORT-CATEGORY AEROPLANES |
IEC 62585:2012 | Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter |
IEC 61094-8:2012 | Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
IEC 61094-6:2004 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
IEEE DRAFT C63.19 : 2005 | METHODS OF MEASUREMENT OF COMPATIBILITY BETWEEN WIRELESS COMMUNICATIONS DEVICES AND HEARING AIDS |
BS EN 62585:2012 | Electroacoustics. Methods to determine corrections to obtain the free-field response of a sound level meter |
CEI EN 62585 : 2013 | ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER |
BS EN 61265:1995 | Electroacoustics. Instruments for measurement of aircraft noise. Performance requirements for systems to measure one-third-octave band sound pressure levels in noise certification of transport-category aircraft |
UNE-EN 61094-8:2013 | Measurement microphones. Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
UNE-EN 62585:2013 | Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter |
I.S. EN 61094-8:2012 | MEASUREMENT MICROPHONES - PART 8: METHODS FOR DETERMINING THE FREE-FIELD SENSITIVITY OF WORKING STANDARD MICROPHONES BY COMPARISON (IEC 61094-8:2012 (EQV)) |
I.S. EN 61094-6:2005 | MEASUREMENT MICROPHONES - PART 6: ELECTROSTATIC ACTUATORS FOR DETERMINATION OF FREQUENCY RESPONSE |
IEC TS 61094-7:2006 | Measurement microphones - Part 7: Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
ISO 9613-1:1993 | Acoustics Attenuation of sound during propagation outdoors Part 1: Calculation of the absorption of sound by the atmosphere |
IEC 61094-8:2012 | Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison |
IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.