• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 61511-1:2017+A1:2017

Current

Current

The latest, up-to-date edition.

Functional safety. Safety instrumented systems for the process industry sector Framework, definitions, system, hardware and application programming requirements

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

28-02-2018

Committee
GEL/65/1
DocumentType
Standard
Pages
92
PublisherName
British Standards Institution
Status
Current

This part of IEC61511 gives requirements for the specification, design, installation, operation and maintenance of a safety instrumented system (SIS), so that it can be confidently entrusted to achieve or maintain a safe state of the process. IEC61511-1 has been developed as a process sector implementation of IEC61508:2010. In particular, IEC61511-1: specifies the requirements for achieving functional safety but does not specify who is responsible for implementing the requirements (e.g., designers, suppliers, owner/operating company, contractor). This responsibility will be assigned to different parties according to safety planning, project planning and management, and national regulations; applies when devices that meets the requirements of the IEC61508 series published in 2010, or IEC61511-1:2016 [11.5], is integrated into an overall system that is to be used for a process sector application. It does not apply to manufacturers wishing to claim that devices are suitable for use in SISs for the process sector (see IEC61508-2:2010 and IEC61508-3:2010); defines the relationship between IEC61511 and IEC61508 (see Figures2 and 3); applies when application programs are developed for systems having limited variability language or when using fixed programming language devices, but does not apply to manufacturers, SIS designers, integrators and users that develop embedded software (system software) or use full variability languages (see IEC61508-3:2010); applies to a wide variety of industries within the process sector for example, chemicals, oil and gas, pulp and paper, pharmaceuticals, food and beverage, and non-nuclear power generation; NOTE1 Within the process sector some applications may have additional requirements that have to be satisfied. outlines the relationship between SIFs and other instrumented functions (see Figure4 ); results in the identification of the functional requirements and safety integrity requirements for the SIF taking into account the risk reduction achieved by other methods; specifies life-cycle requirements for system architecture and hardware configuration, application programming, and system integration; specifies requirements for application programming for users and integrators of SISs. applies when functional safety is achieved using one or more SIFs for the protection of personnel, protection of the general public or protection of the environment; may be applied in non-safety applications for example asset protection; defines requirements for implementing SIFs as a part of the overall arrangements for achieving functional safety; uses a SIS safety life-cycle (see Figure7 ) and defines a list of activities which are necessary to determine the functional requirements and the safety integrity requirements for the SIS; specifies that a H&RA is to be carried out to define the safety functional requirements and safety integrity levels (SIL) of each SIF; NOTE2 Figure9 presents an overview of risk reduction means. establishes numerical targets for average probability of failure on demand (in demand mode) and average frequency of dangerous failures (in demand mode or continuous mode) for each SIL; specifies minimum requirements for hardware fault tolerance (HFT); specifies measures and techniques required for achieving the specified SIL; defines a maximum level of functional safety performance (SIL 4) which can be achieved for a SIF implemented according to IEC61511-1; defines a minimum level of functional safety performance (SIL 1) below which IEC61511-1 does not apply; provides a framework for establishing the SIL but does not specify the SIL required for specific applications (which should be established based on knowledge of the particular application and on the overall targeted risk reduction); specifies requirements for all parts of the SIS from sensor to final element(s); defines the information that is needed during the SIS safety life-cycle; specifies that the design of the SIS takes into account human factors; does not place any direct requirements on the individual operator or maintenance person: NOTE3 IEC61508 is also used by safety instrumented designers, integrators and users where directed in IEC61511. NOTE4 Subclause 7.2.2 in IEC61511-1:2016 and A.7.2.2 in IEC61511-2:2016 contain guidance on handling integration of sub-systems that comply with other standards (such as machinery, burner, etc.).

Standards Relationship
IEC 61511-1:2016/AMD1:2017 Identical
EN 61511-1:2017/A1:2017 Identical

View more information
£314.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.