Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEEE DRAFT 1202 : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

FLAME-PROPAGATION TESTING OF WIRE AND CABLE

Available format(s)

Hardcopy , PDF

Superseded date

23-07-2013

Language(s)

English

Introduction
Participants
Contents
1 Overview
  1.1 Scope
  1.2 Purpose
  1.3 Applications
  1.4 Disclaimer
  1.5 Test Precautions
2 References
3 Definitions
4 Flame Test Facility
  4.1 Enclosure
      4.1.1 Enclosure Walls
      4.1.2 Windows
      4.1.3 Air Intakes
      4.1.4 Access Door
      4.1.5 Exhaust Hood
      4.1.6 Collection Box
  4.2 Exhaust Duct
  4.3 Air Movement with in the Enclosure
  4.4 Cable Tray
  4.5 Burner and Mixer
  4.6 Flowmeters
  4.7 Supply Air
  4.8 Propane
5 Test Sample Requirements
  5.1 Cable Samples
  5.2 Test Required
6 Flame Test Procedure
  6.1 Cable Mounting
      6.1.1 Cables Smaller Than 13 mm (0.51 in)
      6.1.2 Cables 13 mm (0.51 in) and Larger
      6.1.3 Flat Cables
  6.2 Test Procedure
      6.2.1 Cables and Cable Tray
      6.2.2 Exhaust Duct Flow Rate
      6.2.3 Burner
      6.2.4 Air Flow & Air Temperature
      6.2.5 Test Duration
      6.2.6 Supplemental Information
7 Test Evaluation
  7.1 Evaluation of Damage
      7.1.1 Cable Char Damage
      7.1.2 Non-Char Cable Damage
  7.2 Performance Criteria
  7.3 Test Report
Annex A - Burner &Mixer Information
Annex B - Bibliography

Presents a protocol for exposing cable samples to a theoretical 20 kW (70,000 Btu/hr) flaming ignition source for 20-minute test duration. The test determines the flame propagation tendency of single conductor and multi-conductor cables intended for use in cable trays.

DocumentType
Draft
Pages
20
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy

NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
C22.2 NO. 126.1-17 Metal cable tray systems (Binational standard with NEMA VE 1-2017)
IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus

View more information

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more