BS 2G 196:1971
Current
The latest, up-to-date edition.
Specification for static invertors
Hardcopy , PDF
English
19-02-1971
Foreword
1 General
1.1 Scope
1.2 Definitions
1.3 General construction
1.4 Preferred ratings
1.5 Supply characteristics
1.6 Output voltage and frequency
1.7 Efficiency
1.8 Regulation response and stability
1.9 Voltage balance
1.10 Waveform of output voltage
1.11 Modulation of output voltage
1.12 Control of voltage and frequency
1.12.1 Voltage
1.12.2 Frequency
1.13 Adjustment of voltage
1.14 Phase sequence
1.15 Protection
1.15.1 Voltage and frequency
1.15.2 Overload conditions
1.15.3 Short-circuit capacity
1.15.4 Automatic shut down
1.15.5 Reversed input polarity
1.15.6 Input voltage
1.16 Vibration, acceleration and climatic proofness
2 Particular requirements
2.1 Arrangement and construction
2.2 Terminal identification
2.3 Components
2.4 Radio interference
2.5 Compass interference
2.6 Starting
2.7 Cooling
2.8 Declarations
2.9 Marking
2.10 Warning notices
3 Tests
3.1 General
3.2 Test conditions
3.3 Type tests
3.3.1 Starting
3.3.1.1 Normal
3.3.1.2 Reversed input polarity
3.3.2 Voltage and frequency regulation
3.3.3 Transient response
3.3.4 Wave form
3.3.5 Protection
3.3.5.1 Transient voltage and input voltage
3.3.5.2 Output overvoltage
3.3.5.3 Output frequency
3.3.6 Voltage modulation
3.3.7 Efficiency
3.3.8 Input current
3.3.8.1 Maximum current demand
3.3.8.2 Ripple current
3.3.9 Overload voltage
3.3.10 Short-circuit capacity
3.3.11 Insulation resistance
3.3.12 Environmental tests
3.3.13 Cooling test
3.3.14 Temperature and pressure
3.3.15 Fungus growth
3.3.16 Leakage (hermetically sealed equipment)
3.3.17 Waterproofness
3.3.18 Vibration
3.3.19 Acceleration
3.3.20 Explosion proofness
3.3.21 Radio interference
3.3.22 Compass safe distance
3.3.23 Salt corrosion
3.3.24 Dust and sand
3.3.25 Contamination
3.4 Production acceptance tests
3.4.1 Voltage (and frequency) regulation
3.4.2 Reversed input polarity
3.4.3 Transient response
3.4.4 Waveform
3.4.5 Transient voltage and input voltage protection
3.4.6 Output frequency protection
3.4.7 Maximum current demand
3.4.8 Insulation resistance
3.4.9 Phase sequence (three phase invertors only)
3.4.10 Voltage balance (three phase invertors only)
3.4.11 Endurance
3.5 Production quality tests
3.5.1 Sampling
3.5.2 Production quality tests
3.5.2.1 Short-circuit capacity
3.5.2.2 Waveform analysis
3.5.2.3 Temperature and pressure
3.5.2.4 Vibration
3.5.2.5 Further tests
Appendices
A Salt corrosion test
B Dust and sand test
Tables
1 Voltage balance loads
2 Load configurations
3 Non-sinusoidal loads
Figure
1 Measuring device for dust and sand test
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.