Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 2430.3.9:2004

AvailableSuperseded

AvailableSuperseded

An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by Intertek Inform as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

Classification of hazardous areas Examples of area classification - Miscellaneous

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

20-05-2004

Preview

Specifies guidance on the classification of areas associated with several finishing processes, fruit ripening rooms, several batch-type processes and ammonia systems. It includes specific examples of classification for the aforementioned areas. To be read in conjunction with AS/NZS2430.1.

Committee
MS-011
DocumentType
Standard
ISBN
0 7337 5976 9
Pages
17
PublisherName
Standards Australia
Status
AvailableSuperseded
SupersededBy
Supersedes

This Standard provides examples of area classification for areas associated with specialised processes other than those covered by Parts 3.2 to 3.8 of AS/NZS 2430.3. It is part of the AS/NZS 2430.3 series, which recommends the classification of several commonly occurring situations and should be read in conjunction with AS/NZS 2430.3.1.

First published in Australia as part of AS 1076.2-1977.AS 2430.1 first published 1981.AS 1076.2-1977 and AS 2430.1-1981 revised, amalgamated and designated and designated AS 2430.1-1982.AS 2430.1-1982 revised and redesignated in part as AS 2430.3-1987.Second edition 1991.First published in New Zealand as part of NZS 6101P:1972.Revised and redesignated in part as NZS 6101.3:1991.AS 2430.3-1991 and NZS 6101.3:1991 revised, amalgamated and redesignated in part as AS 2430.3.9:1997.Second edition 2004. Originated in Australia as part of AS 1076.2-1977. Originated in New Zealand as part of NZS 6101P:1972. Previous edition AS/NZS 2430.3.9:1997. Second edition 2004.

AS/NZS 4114.1:2003 Spray painting booths, designated spray painting areas and paint mixing rooms Design, construction and testing
AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS/NZS 1677.1:1998 Refrigerating systems Refrigerant classification
AS/NZS 2430.3.1:2004 Classification of hazardous areas Examples of area classification - General
AS/NZS 61241.3:1999 Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present
AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
AS 3754-1990 Safe application of powder coatings by electrostatic spraying
AS 1482-1985 Electrical equipment for explosive atmospheres - Protection by ventilation - Type of protection v (Reconfirmed 2013)
AS/NZS 1677.2:1998 Refrigerating systems Safety requirements for fixed applications

AS 4976-2008 The removal and disposal of underground petroleum storage tanks
AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
AS/NZS 1596:2002 The storage and handling of LP Gas
AS/NZS 4114.1:2003 Spray painting booths, designated spray painting areas and paint mixing rooms Design, construction and testing
AS/NZS 2311:2009 Guide to the painting of buildings
HB 29-2007 Communications cabling manual - Module 2: Communications cabling handbook
AS 4326-2008 The storage and handling of oxidizing agents
AS/NZS 2243.10:2004 Safety in laboratories Storage of chemicals
AS/NZS 1768:2007 Lightning protection
AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS/NZS 4114.2:2003 Spray painting booths, designated spray painting areas and paint mixing rooms - Installation and maintenance
AS/NZS 2022:2003 Anhydrous ammonia - Storage and handling (Reconfirmed 2023)
AS 2714-2008 The storage and handling of organic peroxides (Reconfirmed 2021)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 3780-2008 The storage and handling of corrosive substances
AS/NZS 60079.30.2:2007 Explosive atmospheres Electrical resistance trace heating - Application guide for design, installation and maintenance (IEC 60079-30-2, Ed. 1.0 (2007) MOD)
AS/NZS 4240.1:2009 Remote control systems for mining equipment Design, construction, testing, installation and commissioning (Reconfirmed 2021)
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements
AS/NZS 3788:2006 Pressure equipment - In-service inspection (Reconfirmed 2017)
AS 5034-2005 Installation and use of inert gases for beverage dispensing
HB 13-2007 Electrical equipment for hazardous areas
AS/NZS 2381.2:2006 Electrical equipment for explosive atmospheres - Selection, installation and maintenance Flameproof enclosure d
AS/NZS 2243.2:2006 Safety in laboratories Chemical aspects

View more information
$119.17
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more